Product Description

📋

Product Overview

Model NO.
SY-P012-4_H
Product Name
CO2 Insufflator
Function
Endoscopy Suction Irrigation Pump for Hysteroscope
Pulse Gas Supply
Automatic Adjustment
Range of Flow
10-30L
Package
Carton Box
Capacity
100 Set/Month
💡

Product Description

SY-P012-4_H Hospital equipment Medical endoscopy accessory Heating function CO2 Insufflator

CO2 Insufflator

Laparoscopic CO2 Insufflator is designed for safe and stable laparoscopy surgery. It injects CO2 into the abdominal cavity to create and maintain the operation space, ensuring safety for both the patient and the surgeon.

  • Main supply: AC 220V, 50Hz
  • High-flow: Max 40L/min (Adjustable cycle 10/20/30/40L/min)
  • Set pressure: 5mmHg-25mmHg
  • Integrated heating function
  • Automatic gas supply stop when reaching set pressure
  • Automatic decompression if pressure exceeds 2 mmHg of set value
  • Sound and light alarm for overpressure (4.4kpa±5% / 33mmHg±5%)
⚙️

Technical Specifications

Flow Rate 10-30 L/Min Pressure Control 5-25mmHg
Over Pressure Alarm Yes (Sound & Light) Air Filtration ≥ 0.5um, Filtration Rate ≥ 90%
Dimension 38cm(L) x 31.3cm(W) x 12cm(H) Control Panel 7" LCD Touch Panel
Tube Length (2500+20)mm Optional Extra Smoke Extraction & filtration
📸

Detailed Photos

Detailed View 1 Detailed View 2 Detailed View 3 Detailed View 4 Detailed View 5
Feature Display 1 Feature Display 2 Feature Display 3 Feature Display 4 Feature Display 5 Feature Display 6 Feature Display 7

Frequently Asked Questions

What is the maximum flow rate of this CO2 insufflator?
The device offers a high-flow capacity with a maximum rate of 40L/min, which is adjustable in cycles of 10, 20, 30, and 40L/min.
Does the SY-P012-4_H include a heating function?
Yes, it features an integrated heating function to ensure the CO2 gas is delivered at an appropriate temperature for surgery.
How does the automatic safety system work?
The system automatically stops gas supply when the set pressure is reached. If the pressure exceeds the set value by 2 mmHg, it initiates decompression automatically.
What kind of control interface does it have?
The device is equipped with a user-friendly 7-inch LCD touch panel for easy monitoring and adjustments.
Is there an alarm for overpressure conditions?
Yes, the device includes both sound and light alarms that trigger when the pressure reaches 4.4kpa±5% (33mmHg±5%).
What are the filtration specifications for the gas supply?
The device utilizes an air filtration system for particles ≥ 0.5um with a filtration rate of ≥ 90%.